Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 12(7)2022 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-35885583

RESUMO

A method to detect the presence of infection after Total Joint Arthroplasty is presented. The method is based on Electrical Bioimpedance Spectroscopy and guarantees low latency, non-invasiveness, and cheapness with respect to the state of art. Experimental measurements were carried out on a singular patient who had already undergone bilateral Total Knee Arthroplasty. He was affected by a hematogenous Periprosthetic Joint Infections on the left knee. The right knee was adopted as the reference. Measurements were acquired once before the surgical procedure (Diagnosis Phase) and twice in the postoperative phases (Monitoring Phase). The most relevant frequency range, for diagnosis and monitoring phases, was found to be between 10 kHz to 50 kHz. The healing trend predicted by the decrease of impedance magnitude spectrum was reflected in clinical and laboratory results. In addition, one month after the last acquisition (two months after the surgery), the patient fully recovered, confirming the prediction of the Electrical Bioimpedance Spectroscopy technique.

2.
Polymers (Basel) ; 13(23)2021 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-34883568

RESUMO

A preliminary design of customized antibiotic-loaded poly-methyl-methacrylate (ALPMMA) spacer characterized by an appropriate footprint according to the specific patient's anatomy and a reliable mechanical response to severe functional loads (i.e., level walking and 45° bent knee) is reported. The targeted virtual prototyping process takes origin from a novel patented 3D geometrical conceptualization characterized by added customization features and it is validated by a preliminary FEM-based analysis. Mechanical and thermomechanical properties of the antibiotic-doped orthopedic PMMA cement, which will be used for the future prototype manufacturing, were measured experimentally by testing samples taken during a real day-running orthopedic surgery and manufactured according to the surgeon protocol. FEM analysis results indicate that small area is subjected to intensive stresses, validating the proposed geometry from the mechanical point of view, under the two loading scenarios, moreover the value of safety margins results positive, and this is representative of the lower stress magnitude compared to the critical material limits. The experimental data confirm that the presence of antibiotic will last during the surgeon period moreover, the temperature dependent modulus of the bone cement is slightly affected by the body range temperature whereas it will drastically drop for higher temperature out the range of interest. A complete customization, according to a patient anatomy, and the corresponding real prototype spacer will be manufactured by 3D printing techniques, and it will be validated by destructive testing during the second stage of this activity before commercialization.

3.
J Pers Med ; 11(10)2021 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-34683181

RESUMO

Peri-prosthetic joint infections (PJIs) dramatically affect human health, as they are associated with high morbidity and mortality rates. Two-stage revision arthroplasty is currently the gold standard treatment for PJI and consists of infected implant removal, an accurate debridement, and placement of antimicrobial impregnated poly-methyl-metha-acrylate (PMMA) spacer. The use of antibiotic-loaded PMMA (ALPMMA) spacers have showed a success rate that ranges from 85% to 100%. ALPMMA spacers, currently available on the market, demonstrate a series of disadvantages, closely linked to a low propensity to customize, seen as the ability to adapt to the patients' anatomical characteristics, with consequential increase of surgical complexity, surgery duration, and post-operative complications. Conventionally, ALPMMA spacers are available only in three or four standard sizes, with the impossibility of guaranteeing the perfect matching of ALPMMA spacers with residual bone (no further bone loss) and gap filling. In this paper, a 3D model of an ALPMMA spacer is introduced to evaluate the cause- effect link between the geometric characteristics and the correlated clinical improvements. The result is a multivariable-oriented design able to effectively manage the size, alignment, stability, and the patients' anatomical matching. The preliminary numerical results, obtained by using an "ad hoc" 3D virtual planning simulator, clearly point out that to restore the joint line, the mechanical and rotational alignment and the surgeon's control on the thicknesses (distal and posterior thicknesses) of the ALPMMA spacer is mandatory. The numerical simulations campaign involved nineteen patients grouped in three different scenarios (Case N° 1, Case N° 2 and Case N° 3) whose 3D bone models were obtained through an appropriate data management strategy. Each scenario is characterized by a different incidence rate. In particular, the observed rates of occurrence are, respectively, equal to 17% (Case N° 1), 74% (Case N° 2), and 10% (Case N° 3).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...